
Table of Contents
Simply Supported Beam and Slab
Reinforcement detailing in beams and slabs is critical for delivering strength, longevity, and cost savings. Cover to reinforcement, length of reinforcement, curtailment of reinforcement, quantity and diameter of reinforcement to be provided should all be specified explicitly in the reinforcing details of concrete beams and slabs. The maximum bending moment and shear force occur at a distance of d/2 from the face of the support for a simply supported beam or slab, where d is the effective depth of beam or slab. As a result, bending reinforcement is required at the middle of the span but not at the support, whereas shear reinforcement is required at the support. As a result, it is not required to submit the entire document.
As shown in, for a simply supported beam and slab, 100 percent of the design reinforcement is provided as tension reinforcement at the mid span of the beam and slab, and 50 percent is curtailed at 0.08L from the centre support. Simply Supported Beam and Slab Reinforcement Details Tension steel curtailment in a simply supported beam and slab Continuous Beams and Slabs Reinforcement Details Shear force and bending moment diagrams are generated for continuous beams and slabs, and reinforcing details are provided based on the values of the shear force and bending moment. The tension reinforcement is 100 percent at the mid-span of the beam and slab, as shown in while.
Continuous Beams and Slabs
Shear force and bending moment diagrams are generated for continuous beams and slabs, and reinforcing details are provided based on the values of the shear force and bending moment. The tension reinforcement is 100 percent at the mid-span of the beam and slab, while it is restricted at 0.1 L from the centre of the support at the end support and 0.2L at the intermediate support, as shown in. The beam and slab’s effective length is L.On end supports, shear reinforcements are provided up to 0.1L from the face of the support, and at intermediate supports, shear reinforcements are provided up to 0.3L from the centre of the support Details of Reinforcement.
Beam reinforcement details must be completed in compliance with relevant detailed standards. In addition to the code of practises, additional rules have been produced, such as beam reinforcement, which is described. The typical method of beam reinforcing details is the focus of this essay. First, we look over the BS 8110 Part 1 detailed guidelines. When preparing reinforcement drawings, the following set of requirements must be checked. The standard detailed rule does not apply in all circumstances. The most appropriate way is to specify the reinforcement according to the bending moment variation. For the procedure of curtailment of the top reinforcement, the directions given in the article curtailment of beam reinforcements could be followed Beam Reinforcement Anchorages.
Typical reinforcement detail for concrete beam
The length of the tension anchorage must be calculated using the restraining bar. The column reinforcements are the restrict bars in this case. When the top beam reinforcement must be continued below the beam bottom to maintain the tension anchorage length, the column construction joint must be lowered from the beam bottom or U bars must be provided while the column construction junction is maintained at beam bottom level. The article design anchorage bond stress can be used to determine the anchoring length calculation method.Beam to Beam Join Reinforcement using Beam Hangers The vertical force applied to the supporting beam by the hanging beam when one beam is supported by another. In order to carry this axial force, reinforcing is required. There are several methods for calculating the area of a room.
The proper code of practises and standards method of detailing reinforcements should be followed while describing slab reinforcements.In cast-in-situ concrete, there are three types of slabs.spanning slabs in one direction slabs with a two-way span Slabs that cantilever When slab reinforcement detail drawings are generated, there are identical requirements for one-way and two-way slabs. Let’s have a look at the slab reinforcement details design code need. The BS 8110 Part 01 specifies the slab reinforcing arrangements shown below.Minimum Reinforcement Percentage Provide a 0.13 percent reinforcing area. Bar Anchorage at a Simplely Supported End A straight length of bars can be used if the design ultimate shear stress at the support’s face is less than half the acceptable Vc.
Modern Beam and Slabs
It’s worth noting that the inclinations and magnitudes of principle stresses vary significantly over the cross-section depth and along the beam length in reinforced concrete beams, depending on the presence of bending moment, shear force, axial force, and torsion. As axial stresses are zero at the neutral axis location, they are always inclined at 45 degrees to the longitudinal axis. Because the principal tension stresses originating from either shear alone or the combined action of shear and bending can generate potential cracking in concrete members, they must be appropriately considered in the design. The principle compression controls the direction and amplitude of compression struts, whereas the principle tension (or diagonal tension) governs the “shear stress” capability of concrete sections.
The shuttering should be tough enough to bear the weight of concrete, as well as the effect of concrete placement and vibrations. Shuttering plates should be treated with oil or a mould release agent so that they may be easily removed after the concrete has reached its original strength. Before casting the sloping roof, 12 mm diameter PVC pipe nipples should be provided. After the slab is concreted, these nipples will be handy for cement grout. Grouting is required because, no matter how careful you are when concreting a sloping roof, the slab is susceptible to leaks. The grouting will help to prevent leaks. As per the beam depth, mark one level on each column. Beam bottom supports should be positioned and levelled in relation to the depth of the beam.
Detailing of Reinforcements
The bottom joints of the beams should be correctly supported so that the formwork does not bulge during the concrete pour.Before installing beam sides, make sure the bottom of the beam is level.Bottom bracing should be installed after the beam has been levelled.With the use of a line dori, verify the plumb of the beam sides at each end. The beam column junction shuttering should be plumb and watertight.At the end of the beam, formwork joints on the sides should be taken.All shuttering gaps must be correctly filled before casting a slab, with special attention paid to the column cap, beam junctions, beam side to slab bottom connection, and beam side to beam bottom junction, as well as jointing between two plates.Plates that can be adjusted (gabadi plates or gap plates) should be used.
Contractors employ scrap material in these circumstances since shuttering plates can’t be installed and the slab’s bottom isn’t level. It has an impact on the thickness of the plaster.The thickness of the slab should be marked on the side of the slab according to the thickness of the slab.As much as feasible, wooden props should be avoided. If you’re using wooden props, be sure they’re sound, the right sizes, plumb, and aren’t butt spliced.Tubes and fixed couplers must brace props in both directions.Wooden plates are not suggested because surface deformations provide an uneven surface, causing the thickness of the ceiling plaster to increase.
Side face reinforcement in the web of the beam provided.
In way slab main reinforcement is provided along both direction.
The maximum tension reinforcement of the beam should not be greater than 0.04bD.
Also Check
Methods to Check Verticality of Structure during Building Const